Beisler 100-54 User Manual
Page 43

2-21
Error 43: photo cell
lighted too early
automatic flap length detection with
photo cell enabled; photo cell
detected flap end too early
program security length shorter; switch off monito-
ring (enter 250 mm as seam length); check photo
cell TS31 and foil; reduce sensitivity of photo cell
(in case of reflections)
Error 45 ... 48: I/O DAC,
ULN, 485, RES
internal hardware errors during data
transmission to 9020020
replace 9020020
Error 51: Flap station
does not swing
flap station hasn’t reached active
position within error time
check cylindre, valve Y17, termination switch
TS08
Error 52: Flap station
not in home position
flap station hasn’t reached home
position within error time
check cylindre, valve Y17, termination switch
TS07
Error 53: Pocket pouch
station not in home
position
pocket puch supply hasn’t reached
home position within error time
check cylindre, valves Y18 Y19, termination
switch TS11
Error 54: Station not
locked
folder station isn’t locked