Beisler 100-54 User Manual
Page 42

2-20
Error 27: Pinole not
down
home position not reached within
error time
check cylindre, valve Y59, termination switch
ES39 ES40
Error 28: no impulses
from sewing motor
no impulses from sewing motor
after sewing start (sewing motor
doesn’t move)
check sewing motor and synchronization; check
connection 9020013 > sewing motor; read both
upper diodes at 9020013: left lights shortly when
needle up; right shows synchronization impulses
(512 impulses/rev); if none lights during the hand
wheel is moved: check power supply of sewing
motor, possibly replace sewing motor; if diodes
are functioning and motor makes no move befor
error message, check connection 9020020 >
sewing motor, possibly replace 9020020 or
sewing motor; if motor makes some stitches
before error message, check connection control >
I/O module, possible replace components
Error 29: Sewing motor
too fast
during thread cutting, sewing motor
hasn’t reached cutting speed within
error time
replace sewing motor or synchronizator
Error 30: No thread
cutting position
sewing motor hasn’t reached
cutting position during thread
cutting
enter slower cutting speed; enter earlier cutting
position; replace sewing motor or synchronizator
Error 33: Sewing motor
doesn’t stop
motor doesn’t stop after thread
cutting within error time
enter slower cutting speed; enter earlier cutting
position; replace sewing motor or synchronizator
Error 34: Needle not up
needle is not in upper home positi-
on; together with the error message
the control will try to bring the
needle into upper position again
check sewing motor and synchronizator; check
connection 9020013 > sewing motor; read both
upper diodes at 9020013: if none lights during
hand wheel is turned, check power supply of
sewing motor; possibly replace sewing motor; if
diodes are functioning, check connection 9020020
> sewing motor; possibly replace 9020020
Error 35: Thread brea-
kage
thread monitor reports thread
breakage
Error 36: Spool empty
mode ‘meter counting bobbing
thread’ enabled; remaining length
reached zero
Error 37: Spool only
residual
one of the photo cells at the spool
capsule is lighted, spool empty
if both spools are not empty, one of the photo cells
reflected the thread and must be adjusted less
sensitive
Error 41: No flap
automatic detection of flap length
with photo cell is enabled; photo cell
hasn’t detected a flap during inserti-
on
insert flap; check photo cell TS31 and foil
Error 42: Photo cell not
lighted
automatic detection of flap length
with photo cell is enabled; photo cell
hasn’t detected a flap within safety
length
program safety length longer; switch off monito-
ring (enter 250 mm as seam length); check photo
cell TS31 and foil