Setting dip-switches rs422 – BECKHOFF CX1020 User Manual
Page 44
Product overview
42
Embedded PC
RS485 without Echo, Drop-Point ( without Termination)
DIP
Status
Function
1 off
Echo
on
2 on
Echo
off
3 on
Auto
send
on
4
off
Always send on
5
off
Auto receive on
6
on
Always receive on
7 off
Term
on
8 off
Term
on
RS485 with Echo, Drop-Point ( without Termination)
DIP
Status
Function
1 on
Echo
on
2 off
Echo
off
3 on
Auto
send
on
4
off
Always send on
5
off
Auto receive on
6
on
Always receive on
7 off
Term
on
8 off
Term
on
Setting DIP-Switches RS422:
RS422 full duplex end point
DIP
Status
Function
1 on
Echo
on
2 off
Echo
off
3 off
Auto
send
on
4
on
Always send on
5
off
Auto receive on
6
on
Always receive on
7 on
Term
on
8 on
Term
on
Note
The system interface CX1020-N31 can only be used instead and not at the same time with
system interface CX1020-N030.
The system interface CX1020-N41 can only be used instead and not at the same time with
system interface CX1020-N040.