beautypg.com

BECKHOFF CX1020 User Manual

Page 116

background image

Error handling and diagnostics

114

Embedded PC

CX1100-0004 power supply LEDs

Display

LED

Meaning

PWR

power supply
The LED lights up green when the power supply is correct, but red if
there is a short circuit.

L/A

off

E-Bus is not connected

on

E-Bus is connected / no data traffic on E-bus

blink

E-Bus is connected / data traffic on E-bus

RUN

Indicates the state of the EtherCAT bus:

off

INIT

blink

PRE-OPERATIONAL
(frequency: 200 ms on / 200 ms off)

single
flash

SAVE-OPERATIONAL
(frequency: 200 ms on / 1000ms off)

on

OPERATIONAL

flickering

BOOTSTRAP
(frequency: 50 ms on / 50 ms off)

double
flash

reserved for future use
(frequency: 200 ms on / 200 ms off / 200 ms on / 1000 ms off)

triple
flash

reserved for future use
(frequency: 200 ms on / 200 ms off / 200 ms on / 200 ms off / 200 ms on
/ 1000 ms off)

quadruple
flash

reserved for future use
(frequency: 200 ms on / 200 ms off / 200 ms on / 200 ms off / 200 ms on
/ 200 ms off / 200 ms on / 1000 ms off)

The functions for L/A and RUN LED are available in hardware revision > 2.0. The LEDs have no function in older
revisions.

This manual is related to the following products: