beautypg.com

Sshhuuttddoowwnn ddiiaaggnnoossttiiccss, Lloonngg tteerrm m eevveenntt hhiissttoorryy – Directed Electronics Hornet 564T User Manual

Page 50

background image

5

50

0

© 2005 Directed Electronics, Inc. Vista, CA

sshhuuttddoowwnn ddiiaaggnnoossttiiccss

1. With the ignition OFF, press and H

HO

OLLD

D the Valet/Program button.

2. Turn the ignition ON and then back OFF while H

HO

OLLD

DIIN

NG

G the Valet/Program button.

3. Release the Valet/Program button.

4. Press and release the Valet/Program button. The LED will report the last shutdown for one minute or until

the ignition is turned on.

lloonngg tteerrm

m eevveenntt hhiissttoorryy

The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full

trigger, the older of the two triggers in memory will be replaced by the new trigger. To access long term event

history:

1.

With the ignition off, press and H

HO

OLLD

D the Valet®/Program switch.

2.

Turn on the ignition.

LLEED

D FFLLA

ASSH

HEESS

SSH

HU

UTTD

DO

OW

WN

N M

MO

OD

DEE

One

Timed out

Two

Over-rev shutdown

Three

Low or no RPM

Four

Transmitter shutdown (or optional push-button)

Six

(-) Shutdown (H3/3 GRAY) or (+) Shutdown (H3/4 BROWN)

Seven

(-) Neutral safety shutdown (H3/6 BLACK/WHITE)

Eight

Wait-to-start timed out

ttoo ppeerrffoorrm

m sshhuuttddoow

wnn ddiiaaggnnoossttiiccss