Directed Electronics Hornet 564T User Manual
Page 45
© 2005 Directed Electronics, Inc. Vista, CA
4
45
5
2
2--3
3 N
NU
UIISSA
AN
NCCEE P
PR
REEV
VEEN
NTTIIO
ON
N CCIIR
RCCU
UIITTR
RY
Y™
™ ((N
NP
PCC™
™)) O
ON
N//O
OFFFF:: NPC™ stops repeated triggering of the same zone. If
one zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time of the
third trigger. During that hour, if the system sees a trigger on that zone again, the system resets the one hour
timer. If one hour passes and the zone has not triggered again, the zone is activated and can trigger the system
again. NPC™ only monitors sensor inputs, and does not bypass the door trigger or the ignition trigger at any
time. If NPC™ is turned off, the system will respond to repeated triggers on the sensor inputs and will do so
indefinitely. Some states have laws regulating how many times a security system can trigger before it is consid-
ered a nuisance and the vehicle is towed away.
2
2--4
4 P
PR
RO
OG
GR
REESSSSIIV
VEE D
DO
OO
OR
R TTR
RIIG
GG
GEER
R O
ON
N//O
OFFFF:: The system responds to a door trigger input with a progressive
response. When the door is opened with the system armed, the siren will chirp 10 times prior to the full trig-
gered sequence. The door trigger is still treated as an instant trigger and closing the door quickly will not prevent
full triggered sequence from occurring. If the progressive door trigger is programmed off, the full siren output
will occur the moment the door is opened.
2
2--5
5 V
VA
ALLEETT P
PU
ULLSSEE CCO
OU
UN
NTT 1
1 TTO
O 5
5 P
PU
ULLSSEESS:: The system can be programmed to count the number of presses of the
valet switch before disarming the security system. The factory default setting is one pulse. The unit can also be
set for two to five pulses.
Ghost Switch option: For added security, the GRAY wire on the two-pin Valet®/Program plug can be connected to
any switch in the vehicle that provides a positive (+) momentary pulse.
2
2--6
6 D
DO
OO
OR
R SSEEN
NSSO
OR
R B
BY
YP
PA
ASSSS CCH
HIIR
RP
P O
ON
N//O
OFFFF:: This feature controls the error chirp that is generated if the system is
armed with the door trigger active. This is useful in vehicles that have a long dome light delay after the door
has been closed. If the system is armed before the dome light has turned off, the security system will generate
the door trigger error chirp. If this error chirp is not desired, use this feature to disable the door open error chirp.
If the bypass chirp is turned off, no bypass chirp will be generated, even if a door is accidentally left open.
2
2--7
7 IIG
GN
NIITTIIO
ON
N CCO
ON
NTTR
RO
OLLLLEED
D D
DO
OM
MEE LLIIG
GH
HTT SSU
UP
PEER
RV
VIISSIIO
ON
N O
ON
N//O
OFFFF:: If turned on, the system will turn on the dome
light for 60 seconds when the ignition is turned off. The optional dome light supervision feature must be installed
as described in the Wire Connection Guide.
2
2--8
8 D
DO
OU
UB
BLLEE P
PU
ULLSSEE U
UN
NLLO
OCCK
K O
ON
N//O
OFFFF:: Some vehicles require two pulses on a single wire to unlock the doors. When
the double pulse unlock feature is turned on, the BLUE wire will supply two negative pulses instead of a single
pulse. At the same time, the GREEN wire will supply two positive pulses instead of a single pulse. This makes it
possible to directly interface with double pulse vehicles without any extra parts.
2
2--9
9 FFA
ACCTTO
OR
RY
Y A
ALLA
AR
RM
M D
DIISSA
AR
RM
M W
WIITTH
H CCH
HA
AN
NN
NEELL 2
2:: In the default setting the factory alarm disarm output will disarm