Unpacking / installation, Ac power line, Unpacking – Avery Dennison SNAP 700 Stacker User Manual
Page 10
10 •••• Unpacking / Installation
Users Manual Model 500 Downstacker
AC Power Line
The AVERY DENNISON printer requires that the electric service be 10 Amps @
115VAC or 6 Amps @ 230VAC. This will allow the computer and any additional
support or service equipment to be plugged into the same service.
The AVERY DENNISON 500 downstacker option connects directly to the printer.
The printer controls all the functions of the downstacker option.
Any electrical service that is supplying a AVERY DENNISON printer or peripheral
equipment connected to a AVERY DENNISON printer should follow standard
electrical code practices including proper grounding and neutral requirements.
The AVERY DENNISON printer was designed to operate in an industrial setting for
extended periods of time; however, the printer is controlled by a microprocessor that
is very sensitive to brownouts or power spikes. For this reason as well as the
minimum recommended current supply, AVERY DENNISON recommends that a
separate “clean” service be installed or reserved for the exclusive use of the AVERY
DENNISON printer and its peripherals.
Unpacking / Installation
Unpacking
The AVERY DENNISON 500 stacker is shipped in a cardboard carton that may be
moved by hand.
DO NOT REMOVE THE STACKER FROM THE CARTON OR UNPACK IN
THE SHIPPING / RECEIVING DEPARTMENT.
Items may be lost. Also the carton should be saved for return of the stacker if
ever required. Return shipping damage in a poorly packed carton is the
responsibility of the customer.
Open the carton from the top by cutting the taped seam on the top of the carton.
Remove the foam packing layer. (See Figure 3).
Lift the stacker from the carton by the body of the stacker. Do not lift by the
interface cable or stacker platform.
Remove the plastic over the stacker.