I n t e r p r e t e d Z P L I I ® C o m m a n d s
The following lists the ZPL II
commands interpreted by the MONARCH 9906 printer’s MLI™.
Imaging
ZPL II
Cmds
Notes:
ZPL II
Cmds
Notes:
ZPL II
Cmds
Notes:
^A
^DF
We only support
downloading to RAM.
^IS
^A@
~DG
No rotation of graphics.
~JA
^B2
~DY
No rotation of graphics.
^LH
^B3
~EF
^LL
^B7
If the number of rows or
columns are not
specified, the bar code
size is different.
~EG
Graphics cannot be
erased from within a
format.
^LR
^B8
No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.
^FB
Use only for text
justification.
^LS
^B9
No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.
^FD
^LT
^BA
^FH
^MU
^BB
Supports CODABLOCK F
^FN
^PO
^BC
^FO
^RT
Does not read an RFID
tag, but is required if an
^HV command is used.
^BD
Supports modes 2, 3,
and 4.
^FR
^SF
^BE
No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.
^FS
^XA
^BK
^FT
The X and Y coordinates
must be specified.
^XF
^BL
^FV
This command works the
same as the ^FD
command.
^XG
No magnification.
^BM
The printer only uses
one mod-10 check digit.
^FW
^XZ
^BU
No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.
^F X
^B X
The bar code size is
different. Only use the
value of 200 for the error
correction level, no
rectangular symbols or
custom formats.
^GB
No support for rounded
corners.
^BY
^GF
No rotation of graphics.
^CF
^ID
~DB
No support for double-
wide character fonts.
^IL