Interpreted zpl ii® commands, Imaging, Parser – Avery Dennison Monarch 9855 MLI User Manual
Page 2

ZPL II is a registered trademark of ZIH Corp. ZIH Corp. and Avery Dennison are not related in any way, and ZIH Corp. has
not licensed or otherwise sponsored the MONARCH® printers or the MONARCH LANGUAGE INTERPRETER™.
2
I n t e r p r e t e d Z P L I I ® C o m m a n d s
The following is the list of ZPL II commands interpreted by the MONARCH 9855 printer’s
MONARCH LANGUAGE INTERPRETER™.
Imaging
ZPL II
Cmds
Notes:
ZPL II
Cmds
Notes:
ZPL II
Cmds
Notes:
^A
^DF
We only support
downloading to RAM.
^GF
No rotation of graphics.
^B2
~DG
No rotation of graphics.
^ID
^B3
~DY
No rotation of graphics.
^IL
No support for bar
codes in images.
^B7
If the number of rows or
columns is not
specified, the bar code
size is different.
~EF
^IS
No support for bar
codes in images.
^B8
We support o, h, and f.
~EG
Graphics cannot be
erased from within a
format.
~JA
^B9
We support o, h, f, and
e.
^FB
Use only for text
justification.
^LH
^BA
^FD
^LR
Applies to text, line, or
box fields.
^BC
We support modes N, A,
and D.
^FH
^LS
^BD
We support modes 2, 3,
and 4.
^FN
^LT
^BE
We support o, h, and f.
^FO
^MM
We support t and c.
^BK
^FR
Applies to text, line, or
box fields.
^MU
^BL
^FS
^RF
No support for ^RFr or
^RFe.
^BM
The printer only uses
one mod-10 check digit.
^FT
The X and Y
coordinates must be
specified.
^RT
Does not read an RFID
tag, but is required if an
^HV command is used.
^BU
We support o, h, f, and
e.
^FV
This command works
the same as the ^FD
command.
^WT
Number of retries, etc.
are not used.
^BX
The bar code size is
different. Only use the
value of 200 for the
error correction level,
no rectangular symbols
or custom formats.
^FW
^XA
^BY
^FX
^XF
^CF
^GB
No support for rounded
corners.
^XG
No magnification.
~DB
No support for double-
wide character fonts.
^XZ
Parser
ZPL II
Cmds
ZPL II
Cmds
^CC ~CC
^CM