Nsert, Nstallation – Avalon Firestyles 900 PI-1993 to 1996 User Manual
Page 27
![background image](https://www.manualsdir.com/files/772767/content/doc027.png)
I
NSERT
I
NSTALLATION
(C
ONT
.)
P
AGE
27
H
Install the panels and brass trim to complete the installation. Included with the floor
shield kit are two pairs of side panels. The set that are flat are used, the bent pair can be
discarded. Attach the side panels to the side bays by placing them with the magnetic strip
side up against the side bay. Read the section "Operating the Heater" prior to plugging in
the insert and operating.
3" Minimum
Type "L" Vent
Flashing
3" Clearance
Approved
Ceiling Support
Outside Air
Framing
Wall Covering
Floor Shield
Top Panel
(3/8" space
between top
panel and wall
covering - do
not seal)
Floor covering must be
removed under insert
2'
Min.
If the termination is below the eave,
it must maintain a 2' clearance
1'
Min.
Approved
Wall
Thimble
3"
Min.
Approved thimble
Joints must be
screwed together
and sealed
Support
bracket
every 5'
3"
Min.
12"
Min.
See the
notes to
the left
VERTICAL INSTALLATION*
HORIZONTAL INSTALLATION*
* FOR A FULL LIST OF PELLET
VENT REQUIREMENTS, SEE
THE SECTION "PELLET VENT
REQUIREMENTS" IN THE
PELLET STOVE INSTALLATION
PORTION OF THIS MANUAL
(PAGES 8 THROUGH 10).
2' Min.
3/8" Space
(Do not seal)
Joints must be
screwed together
and sealed
Optional
vertical exterior