Tove, Nstallation – Avalon Firestyles 900 PI-1993 to 1996 User Manual

Page 14

background image

P

AGE

14

S

TOVE

I

NSTALLATION

(C

ONT

.)

Interior Vertical Installation

The interior vertical installation requires an elbow, "Tee", or center flue adapter. It is important
to take into consideration the depth of the elbow, "Tee", or center flue adapter when determining
the placement of the stove. Elbows and "Tee's" vary in depth among manufacturers and affect
the minimum 3" pellet vent clearance to the backwall. For improved rear clearance, use the
Travis Industries center flue adapter (available at your dealer). Make sure to follow all of the
requirements listed in the section "Stove Requirements" as well as those listed below in the
illustration. The steps below detail the order of installation.

HINT:

Install the elbow, "Tee", or center flue adapter before you start the
installation so that an accurate measurement can be made for the
distance between the stove and the backwall.

A

Install the floor protection.

B

Install the pellet vent (it must maintain a 3" clearance). The pellet vent may pass through
the ceiling and roof before termination or turn sideways and terminate along an outside
wall (see the illustration below). Make sure to follow the pellet vent manufacturer's
instructions for passing the vent through combustible walls, ceilings, or roofs. Screw
together all pellet vent joints and seal. Install the outside air connection (if applicable).

C

Place the pellet stove in position and attach the pellet vent and outside air connection (if
applicable). Screw together and seal the pellet vent connection to the stove.

D

Read the section "Operating the Heater" prior to plugging in the stove and operating.

Sidewall

Floor
protection

9"

Min.

0"

0"

3"

Min.

Backwall

Outside
Air

3" Minimum

Joints must
be screwed

together and

sealed

Floor protection

under "Tee"

Type "L" Vent

Flashing

Min.2'

3" Clearance

Approved

Ceiling

Support

6"
Min.

Outside Air

2'

Min.

If the termination

is below the eave,

it must maintain a

2' clearance

1'

Min.

Approved

Wall

Thimble