Avalon Firestyles 900 PI-1993 to 1996 User Manual
Page 10

P
AGE
10
S
TOVE
I
NSTALLATION
(C
ONT
.)
Pellet Vent Termination (See the illustration below)
¥
Must have an approved cap (to prevent water from entering) or a 45
o
downturn
¥
If the termination is located on a windy side of the house, an approved house
shield is recommended to prevent soot from building up on the side of the house
¥
Must not be located where it will become plugged by snow or other material
A
Minimum 4' clearance below or beside any door or window that opens
B
Minimum 1' clearance above any door or window that opens
C
Minimum 2' clearance from any adjacent building
D
Minimum 7' clearance above any grade when adjacent to public walkways
E
Minimum 2' clearance above any grass, plants, or other combustible materials
F
Minimum 3' clearance from any forced air intake of any other appliance
G
Minimum 2' clearance below eaves or overhangs
H
Minimum 1' clearance horizontally from combustible wall
X
Must be a minimum of 2' above the roof
C
B
D
E
A
G
X
A
F
H
O
UTSIDE
A
IR
R
EQUIREMENTS
¥
Required for mobile homes
¥
Must not be drawn from an enclosed space (garage, unventilated crawl space)
¥
Must not be over 15' long
¥
Must be made with 1 3/4" diameter or larger
metal or aluminum duct with a metal screen
attached to the end to keep out rodents
(P.V.C. or other combustible materials may
not be used)
¥
The outside air connects to the outside air
inlet 3 3/16" from the center of the stove and
the distance listed below for the type of legs
used (see the illustration to the right):
Pedestal
13 1/4"
Brass Legs
9 7/8"
Cast Legs
9 7/8"
Black Legs
8 1/2"
Center Line
3 3/16"
See the Table
Outside Air Inlet
(1 3/4" Outside Dia.)