Mantel Requirements

The mantel (combustible or non-combustible) must be a minimum 50” above the base of the
fireplace (see Figure 28).

The maximum mantel depth is 12” (measured from the face).

Max. 12”

Base of the Fireplace

Min. 50”

Mantel

(combustible or non-combustible)

Combustible mantel columns (legs) that

protrude more than 3/4” from the glass

frame must meet the sidewall clearance (11”

from the glass frame). If they protrude 3/4”

or less, they must meet the facing clearance

(6-1/2” from the glass frame).

Non-combustible mantel columns do not

have a minimum clearance.

Figure 28