Page 35: Hearth requirements – recessed hearth
![background image](https://www.manualsdir.com/files/772729/content/doc035.png)
Installation
(for qualified installers only)
35
© Travis Industries
4090807
100-01193_003
Hearth Requirements – Recessed Hearth
A hearth is not required if raised 6” above the flooring surface.
NOTE: Make sure to accommodate the flooring surface - this
distance must be measured from the top of carpeting or other
flooring material.
WARNING:
We recommend a hearth to protect the flooring
surface from discoloration or other negative
impact from the heater, especially if it is near the
minimum raised height.
Min. 6”
Side View
Fireplace
NOTE: When building a raised fireplace, consider the facing
material below the fireplace. If using tile, you may wish to
make the platform a suitable height for un-cut tile. For
example, if using 12” tile, make the platform 10-1/2” tall (10”
section of framing + 1/2” plywood).
1-1/2”
Cement Board
Plywood (OSB, etc.)
Framing
Sub-Floor
Minimum 6” to top of
flooring surface
(carpet, etc.)
Carpet
Figure 24