Installation

(for qualified installers only)

© Travis Industries

4090807

100-01193_003

Approved Vent Configurations

Restrictor Position

Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and
exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor
positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.

Exhaust Restrictor Adjustment

Loosen these screws on

the exhaust restrictor.

Slide the restrictor to the

correct restrictor

position (see the

illustration below). In
this example, the

restrictor is set in

position # 2.

Tighten the screws once

the restrictor is in the

correct position.

(open - stock position) #1

#2

#3
#4

Back Wall of Firebox

Firebox Roof

Figure 17

Intake Restrictor Adjustment

The intake restrictor is shipped in the forward position (pulled towards the glass. To change the intake
restrictor to the back position (pushed toward the back of the firebox), follow the directions below.

Intake Air Restrictor

Loosen these

two screws.

Slide the restrictor back

and tighten the screws.

Figure 18