28 installation, Approved vent configurations, For qualified installers only) – Avalon Firestyles 1080 CF Installation User Manual
Page 28: Restrictor position, Exhaust restrictor adjustment, Intake restrictor adjustment
28
Installation
(for qualified installers only)
© Travis Industries
4090807
100-01193_003
Approved Vent Configurations
Restrictor Position
•
Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and
exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor
positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.
Exhaust Restrictor Adjustment
Loosen these screws on
the exhaust restrictor.
Slide the restrictor to the
correct restrictor
position (see the
illustration below). In
this example, the
restrictor is set in
position # 2.
Tighten the screws once
the restrictor is in the
correct position.
(open - stock position) #1
#2
#3
#4
Back Wall of Firebox
Firebox Roof
Figure 17
Intake Restrictor Adjustment
The intake restrictor is shipped in the forward position (pulled towards the glass. To change the intake
restrictor to the back position (pushed toward the back of the firebox), follow the directions below.
Intake Air Restrictor
Loosen these
two screws.
Slide the restrictor back
and tighten the screws.
Figure 18