Basic input output system – Artesyn PrAMC-7311 Installation and Use (June 2014) User Manual
Page 114

Basic Input Output System
PrAMC-7311 Installation and Use (6806800P34D)
114
Extended RAM Failed at offset:
nnnn
Extended memory not working or not
configured properly at offset nnnn
Contact your local sales
representative or services for
further support.
nnnn Extended RAM Passed
nnnn represents amount of RAM in MBs
successfully tested.
None
Failing Bits: nnnn
nnnn is a map of the bits at the RAM
address (in system, extended or shadow
memory) which failed the memory test.
Each 1 (one) in the map indicates a failed
bit.
Contact your local sales
representative or services for
further support.
Fail-Safe Timer NMI Failed
ServerBIOS2 test error: Fail-save timer
takes too long
None
Incorrect Drive A type - run
SETUP
Incorrect Drive B type - run
SETUP
Type of floppy drive not correctly
identified in setup
Check for correct floppy
drive in setup.
I/O Device IRQ Conflict
I/O device IRQ conflict error
Resolve conflict in setup.
Keyboard controller error
Keyboard controller failed test
Replace keyboard
Keyboard error
Keyboard not working
Check for correct keyboard
connection.
Keyboard error nnn
BIOS discovered a stuck key and displays
scan code nn for stuck key.
Replace keyboard, check for
stuck keys.
Keyboard locked - Unlock key
switch
Keyboard locked.
Unlock the system to
proceed
Memory Size found by POST
different from CMOS
Memory size found by POST is different
from the one stored in CMOS
None
Monitor type does not match
CMOS - Run SETUP
Monitor type not correctly identified in
setup
None
Operating system not found
Operating system cannot be located on
either drive A: or drive C:.
Enter setup and check if fixed
disk and drive A: are properly
identified.
Table 6-33 Example BIOS Messages (continued)
Message
Explanation
Corrective Action