beautypg.com

Artesyn MVME7616E Transition Module Installation and Use (April 2015) User Manual

Page 26

background image

Hardware Preparation and Installation

MVME7616E Transition Module Installation and Use (6806800A43D)

26

4. If necessary, move some of the other modules to allow space for the cables

connected to the P2 adapter and the transition module.

5. Install the jumper on header J1 (on the 3-row P2 adapter or header J5 on the 5-row

P2 adapter) if you are supporting SCSI devices.

6. Attach the P2 adapter, for either the 3-row or 5-row version, to the backplane

connector that is directly in line with the P2 connector on the host VMEmodule.

7. Orient pin 1 of the P2 adapter’s connector with pin 1 of the backplane connector.

8. Attach the 64-conductor cable (furnished with the MVME761-0x1) to the P2

adapter (J3 on the 3-row version, J4 on the 5-row version). Be sure to orient cable
pin 1 with connector pin 1.

9. Attach the 64-conductor cable to connector P2 on the transition module. Be sure

to orient cable pin 1 with connector pin 1.

10.Insert the transition module into the chassis slot, and tighten the attaching screws.

Make sure there is good contact with the transverse mounting rails in order to
minimize RF emissions.

11.Install the chassis cover, making sure that cables are not pinched by the cover.

12.Connect the power cable to the AC power source.