beautypg.com

8 thermal management, Figure 4-4, Board thermal management – Artesyn COMX-P4080-2G-ENP2 Installation and Use (August 2014) User Manual

Page 40: Functional description

background image

Functional Description

COMX-P4080-2G-ENP2 Installation and Use (6806800P63B)

40

4.8

Thermal Management

COMX-P4080-2G-ENP2 provides a thermal management strategy. This includes CPU junction
temperature monitoring.The following diagram shows thermal management strategy:

A thermal diode is integrated in P40x0, which connects to a thermal sensor ADT7411. The CPU
can get the junction temperature via I2C.

When the junction temperature goes up to105

o

C, ADT7411 drives INT# to low, indicates an

interrupt to CPU. A red LED D17 can show the interrupt status.

Figure 4-4

Board Thermal Management

LED

Definition

Definition

Description

D17

INT# signal is active

ON

The CPU temperature
goes up to 105

o

C

OFF

Normal status