Functional Description

COMX-P2020 COM Express Module Installation and Use (6806800K97D)

81

P_HRESET_REQ# is sent to M41ST85WMX6TR's RSTIN2_N, which needs a minimum 100ms of
low voltage level to trigger reset. This is critical because the software programmer may neglect
this and fail in resetting the circuit.

4.7

LM75CIM-3

The LM75 is a temperature sensor which can assert interrupt through IRQ5. There are four data
registers in the LM75 which are selected by the Pointer register.

Figure 4-4

Reset Logic