beautypg.com

3 power requirements, 2 unpacking and inspecting the module, Table 2-3 – Artesyn COMX-P1022 Installation and Use (July 2014) User Manual

Page 35: Board power supply current requirements, Hardware preparation and installation

background image

Hardware Preparation and Installation

COMX-P1022 COM Express Module Installation and Use (6806800M04C)

35

2.1.3

Power Requirements

2.2

Unpacking and Inspecting the Module

Table 2-3 Board Power Supply Current Requirements

0.75V

1.0V

1.2V

1.5V

1.8V

2.5V

3.3V

CPU(P1022)

6000

1000

100

200

DDR3

600

4400

USB PHY(3315)

55

USB HUB(2514)

415

GE PHY BCM5482

260

88

DS90C385

493

TFP410PAP

250

74LVCH32244A x2

120

Total 23.17W

0.45W 6W

3.12W 8.1W

0.5W

5W

Damage of Circuits
Electrostatic discharge and incorrect installation and removal of the product can damage
circuits or shorten its life.
Before touching the product make sure that you are working in an ESD-safe environment or
wear an ESD wrist strap or ESD shoes. Hold the product by its edges and do not touch any
components or circuits.