beautypg.com

2 power requirements, Table 4-2, Dc board power requirements – Artesyn Centellis 2000 User Card-10GE with Telco Alarm Installation and Use (May 2014) User Manual

Page 43: Board exchange

background image

Board Exchange

Centellis 2000 User Card 10GE with Telco Alarm Installation and Use (6806800M46B)

43

4.2.1.2

Power Requirements

Make sure that the board is used in Centellis 2000 AdvancedTCA shelf. If the module is used in
a Centellis 2000 DC version shelf, make sure it is connected to -48 VDC up to -60 VDC (rated
voltage), according to Telecommunication Network Voltage (TNV-2).

A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra-
low-voltage (SELV) under normal operating conditions, and which is not subject to over
voltages from telecommunication networks.

On board voltages are 5.0 VDC, 3.3 VDC, and 1.0 VDC:

5.0 V voltage is generated from the -48 V AdvancedTCA power by a DC/DC converter with
galvanic isolation suitable for TNV-2 circuits.

3.3 V and 1.0 V voltages are derived from the 5.0 V power.

Shock

Half-sine, 11 mSec, 30 m/Sec

2

Blade level packaging
Half-sine, 6 mSec at 180 m/Sec

2

Free fall

-

200 mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(Blade level packaging)
100 mm (unpackaged) per GR-63-CORE

Table 4-1 Environmental Requirements (continued)

Feature

Operating

Non-Operating (packed state)

Table 4-2 DC Board Power Requirements

Feature

Value

Rated Voltage

-48 VDC to -60 VDC
US and Canada: -48 VDC

Operating Voltage

-39 VDC to -72 VDC
US and Canada: -39 VDC to -60 VDC

Input current

Typical with SFP+ module 0.11 A, Maximum with SFP+
module 0.16 A

Centellis 2000 User Card 10GE with Telco
Alarm power dissipation

Typical with SFP+ module 5.7 W, Maximum with SFP+
module 7.9 W, without SFP+ module substrate 1.0 W