beautypg.com

2 sensors, Table 3-3, Controls, indicators and connectors – Artesyn Centellis 2000 User Card-10GE with Telco Alarm Installation and Use (May 2014) User Manual

Page 38

background image

Controls, Indicators and Connectors

Centellis 2000 User Card 10GE with Telco Alarm Installation and Use (6806800M46B)

38

3.2

Sensors

The IPMC functionality is based on the IPMI specification V1.5.

The IPMI sensors on the Centellis 2000 User Card 10GE with Telco Alarm are shown in

Table 3-3

.

For further information, refer Centellis 2000 User Card 10 GE with Telco Alarm: Control via IPMI
Programmer’s Reference.

Table 3-3 Centellis 2000 User Card 10GE with Telco Alarm Specific Sensors

Sensor Name

Sensor Type Code
Description

Generate
Event

Event/ Reading Type
Code

HotSwap HotSwap (F0h)

Hot swap sensor Yes

Sensor specific (6Fh)

Ejector_State Button (14h)

Ejector state
sensor

-

Sensor specific (6Fh)

IPMC_State OEM (D5h)

IPMC state OEM
sensor

-

Sensor specific (6Fh)

IPMB0_State IPMB (F1h)

IPMB0 state
sensor

-

Sensor specific (6Fh)

SFP_Enable Other FRU (1Ah)

Enable/Disable
SFP Writable OEM
sensor

No

Type enable (9)

SFP_TXDIS Other FRU (1Ah)

SFP TXDIS signal

Yes

Reading type failure (4)

SFP_LOS Other FRU (1Ah)

Loss of signal
indication

Yes

Reading type failure (4)

SFP_TXFAULT Other FRU (1Ah)

SFP transmit fault Yes

Reading type failure (4)

SFP_PRESENT Other FRU (1Ah)

SFP presence
sensor

Yes

Presence (8)

PMD_LOSS_SIGNAL Monitor IC (26h) Loss of signal

indication

Yes

Reading type failure (4)

PMD_CMU_LOCK Monitor IC (26h)

PMD CMU Lock
detect

Yes

Reading type failure (4)

PMD_LinkAlarm Monitor IC (26h)

Loss of signal
indication

Yes

Reading Type failure (4)

PMD_CDR_LOCK Monitor IC (26h)

PMD CDR Lock
detect

Yes

Reading type failure (4)