Argox OS Series User Manual
Page 40
78
Connection with host
Host 25S
Printer 9P
Host 9S
Printer 9P
(PC or compatible)
(PC or compatible)
DTR 20 …… 1 DSR
DTR 4
…… 1 DSR
DSR 6 …… 6 DTR
DSR 6
…… 6 DTR
TX 2
…… 2 RX
TX 3
…… 2 RX
RX 3
…… 3 TX
RX 2
…… 3 TX
CTS 5
…… 7 RTS
CTS 8
…… 7 RTS
RTS 4
…… 8 CTR
RTS 7
…… 8 CTS
GND 7 …… 5 GND
GND 5
…… 5 GND
Alternatively you can just connect the 3 wires in the following way.
Host 25S
Printer 9P
Host 9S
Printer 9P
(PC or compatible)
(PC or compatible)
TX 2
…… 2 RX
TX 3
…… 2 RX
RX 3
…… 3 TX
RX 2
…… 3 TX
GND 7 …… 5 GND
GND 5
…… 5 GND
pin 4
pin 4
pin 5
pin 6
pin 6
pin 7
pin 20
pin 8
The simplest way to connect to other hosts (not PC compatible) or
terminals is:
79
Printer
Terminal/Host
Pin 2- RxData ……… TxData
Pin 3- TxData ……… RxData
Pin 5- Ground ……… Ground
In general, as long as the data quantity is not too large and you
use Xon/Xoff as flow control, it will be problem free.
Baud rate:
2400, 4800, 9600(default), 19200, 38400,
57600, 115200 bauds
.(programmable by
command)
Data format: always 8 data bits, 1 start bit and 1 stop bit.
Parity: always non parity
Handshaking: XON/XOFF as well as CTS/RTS (hardware flow
control).
If you run an application with the bundled printer driver under
Windows and use the serial port, you should check the above
parameters and set the flow control to "Xon/Xoff "or "hardware".