Type db9) – Aplex Technology ACS-2685 User Manual
Page 36

ACS-2685 User Manual
36
RS422 Type (option)
RS485 Type (option)
Signal Name
Pin#
Pin#
Signal Name
422_RX+
1
1
NC
422_RX-
2
2
NC
422_TX-
3
3
485-
422_TX+
4
4
485+
Ground
5
5
Ground
NC
6
6
NC
NC
7
7
NC
NC
8
8
NC
NC
9
9
NC
Note:
Use COM3 RS422 or RS485 Function, please enter BIOS CMOS Setup. Path:
BIOS Setup Utility \ Advanced /Super IO Configuration \ Serial Port3 Type:
[RS-485]
[RS-422]
JP4:
(2.0mm Pitch 2x10 Pin Header) COM4 function setting jumper.
Function
JP4 Pin#
RS232
Close: 3-5,4-6,10-12,11-13 (Default)
RS422
Close: 1-3,2-4,5-7,8-10,9-11,12-14,18-20
(option)
RS485
Close: 5-7,8-10,9-11,12-14,16-18 (option)
COM4:
(Type DB9),
I/O serial port, it provides selectable RS232/RS422/RS485 serial
signal output.
COM4 RS232 Type (Default):
Pin#
Signal Name