Aplex Technology ARCHMI-716 User Manual
Page 98

ARCHMI-7XX (SBC-7106A) User Manual
97
Calibrate
This function offers two ways to calibrate your touch screen. ‘Standard Calibration’
adjusts most touch screens. ‘Advanced Calibration’ adjusts aging touch screens.
Standard Calibration Click this button and arrows appear pointing to red squares.
Use your finger or stylus to touch the red squares in
sequence. After the fifth red point calibration is complete. To
skip, press ‘ESC’.
Advanced Calibration Advanced Calibration uses 4, 9, 16 or 25 points to effectively
calibrate touch panel linearity of aged touch screens. Click
this button and touch the red squares in sequence with a
stylus. To skip, press ESC’.
Command Calibration Command call calibration function. Use command mode call
calibration function, this can uses Standard, 4, 9, 16 or 25
points to calibrate E.g. Please run ms-dos prompt or command
prompt c:\Program Files\PenMount Universa
Driver\Dmcctrl.exe -calibration 0 ( Standard Calibration)
Dmcctrl.exe - calibration ($) 0= Standard Calibration
4=Advanced Calibration 4 9=Advanced Calibration 9
16=Advanced Calibration 16 25=Advanced Calibration 25
Step 1. Please select a device then click “Configure”. You can also double click the
device too.