2 software functions, 1 software functions (resistive touch) – Aplex Technology ARCHMI-716 User Manual
Page 97
ARCHMI-7XX (SBC-7106A) User Manual
96
Step 13. Click Yes to do 4 point calibration.
5.2.1 Software Functions (Resistive Touch)
Upon rebooting, the computer automatically finds the new 6000 controller board.
The touch screen is connected but not calibrated. Follow the procedures below to
carry out calibration.
1. After installation, click the PenMount Monitor icon “PM” in the menu bar.
2. When the PenMount Control Panel appears, select a device to “Calibrate.”
PenMount Control Panel(Resistive Touch)
The functions of the PenMount Control Panel are Device, Multiple Monitors , Tools
and About, which are explained in the following sections.
Device
In this window, you can find out that how many devices be detected on your system.