Analog Way Smart Vu LE - SVU200 Programmer's Guide User Manual
Page 30

30
Group
Name
Cmd Resp Description
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
OBLACK
OB OB Output black control
Rd/Wr 0
1
0
0 = Normal output
1 = Black output
0 = Main output
OUTIL_H
OH OH Output H size
Rd
0
65535 1600
Unit = pixels
0 = Main output
OUTIL_V
OV OV Output V size
Rd
0
65535 1200
Unit = pixels
0 = Main output
OFIELDRATE
OT OT Output frame frequency
Rd
100
10000 6000
Unit = 1/100Hz
0 = Main output
OIMAGE_OVERSCAN
OO OO Image Overscan / Underscan
Rd/Wr 0
1
0
0 = Main output
OSETDETECTHDCP
Oh
Oh
Enable/disable the Output HDCP
detection
Rd/Wr 0
4
1
0 = Disable HDCP detection
1 = Automatic HDCP detection
2 = HDCP Configuration 1
3 = HDCP Configuration 2
4 = HDCP Configuration 3
0 = Main output
OISHDCP
On
On Output HDCP status
Rd
0
1
0
0 = Main output
REFERENCE
REFREQUEST
Xr
Xr
Framelock source requested by
user
Rd/Wr 0
14
0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
12 = SDI 3 input as reference
13 = SDI 4 input as reference
14 = Back End 1 as reference
0 = Main output
REFCURRENTREQUEST
Xe
Xe
Current Frame Lock source
Rd/Wr 0
14
0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
12 = SDI 3 input as reference
13 = SDI 4 input as reference
14 = Back End 1 as reference
0 = Main output
REFMODE
Xm Xm Follow mode requested by user
Rd/Wr 0
5
0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
REFCURRENTMODE
Xc
Xc
Current follow mode
Rd/Wr 0
5
0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output