Group

Name

Cmd Resp Description

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

PE_CLOSING_DURATION

cD

cD

Layer closing transition duration

Rd/Wr 0

255

10

Unit = 1/10s

0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4

2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2

PRESET
CONTROL

TAKE

TK

TK

TAKE, Next preset becomes
Current

Rd/Wr 0

1

0

TAKEAVA

TA

TA

Available TAKE flag

Rd

0

1

1

TAKEINFO

TI

TI

TAKE information

Rd

0

2

0

0 = 1 shot TAKE
1 = 2 shot TAKE
2 = Sequenced TAKE

TBAR

NT

NT TBAR value

Rd/Wr 0

10000 0

Unit = 0,01%

COPY_FROM

Nf

Nf

Source for preset copy

Rd/Wr 0

6

0

0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4

COPY_TO

Nt

Nt

Destination for preset copy

Rd/Wr 0

6

0

0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4

COPY_CTRL

Nc

Nc

Preset copy control

Rd/Wr 0

1

0

Auto reset

PREVIEWED_LAYER

NC NC

Previewed layed (layer that is
visible on preview screen)

Rd/Wr 2

7

2

2 = Background Layer for output
1
8 = Audio Output 1
9 = Audio Output 2

SET_QUAD_LAYOUT

NQ NQ

Quadravision Layout request
(auto-reset)

Rd/Wr 0

25

0

SETTINGS

R_FLICK

Rf

Rf

Anti-flicker level

Rd/Wr 0

7

2

0 = No antif-flicker

0 = Main output

R_GAMMA

Rg

Rg

Gamma correction level

Rd/Wr 5

40

10

Unit = 1/10

0 = Main output

R_SHARPNESS

Rs

Rs

Sharpness correction Level

Rd/Wr 0

255

128

128 = neutral

0 = Main output