Analog Way Smart Vu LE - SVU200 Programmer's Guide User Manual
Page 26

26
Group
Name
Cmd Resp Description
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
PE_CLOSING_DURATION
cD
cD
Layer closing transition duration
Rd/Wr 0
255
10
Unit = 1/10s
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2
PRESET
CONTROL
TAKE
TK
TK
TAKE, Next preset becomes
Current
Rd/Wr 0
1
0
TAKEAVA
TA
TA
Available TAKE flag
Rd
0
1
1
TAKEINFO
TI
TI
TAKE information
Rd
0
2
0
0 = 1 shot TAKE
1 = 2 shot TAKE
2 = Sequenced TAKE
TBAR
NT
NT TBAR value
Rd/Wr 0
10000 0
Unit = 0,01%
COPY_FROM
Nf
Nf
Source for preset copy
Rd/Wr 0
6
0
0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4
COPY_TO
Nt
Nt
Destination for preset copy
Rd/Wr 0
6
0
0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4
COPY_CTRL
Nc
Nc
Preset copy control
Rd/Wr 0
1
0
Auto reset
PREVIEWED_LAYER
NC NC
Previewed layed (layer that is
visible on preview screen)
Rd/Wr 2
7
2
2 = Background Layer for output
1
8 = Audio Output 1
9 = Audio Output 2
SET_QUAD_LAYOUT
NQ NQ
Quadravision Layout request
(auto-reset)
Rd/Wr 0
25
0
SETTINGS
R_FLICK
Rf
Rf
Anti-flicker level
Rd/Wr 0
7
2
0 = No antif-flicker
0 = Main output
R_GAMMA
Rg
Rg
Gamma correction level
Rd/Wr 5
40
10
Unit = 1/10
0 = Main output
R_SHARPNESS
Rs
Rs
Sharpness correction Level
Rd/Wr 0
255
128
128 = neutral
0 = Main output