Analog Way Eikos LE - EKS400 Programmer's Guide User Manual
Page 65
65
Group
Name
Cmd RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
REFERENCE
REFREQUEST
Xr
Xr
Framelock source requested by
user
Rd/Wr 0
16
0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
4 = Analog input 5 as reference
5 = Analog input 6 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
12 = SDI 3 input as reference
13 = SDI 4 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
16 = Back End 3 as reference
0 = Main output
1 = Preview output
2 = Recording
output
REFCURRENTREQUEST
Xe Xe
Current Frame Lock source
Rd/Wr 0
16
0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
4 = Analog input 5 as reference
5 = Analog input 6 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
12 = SDI 3 input as reference
13 = SDI 4 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
16 = Back End 3 as reference
0 = Main output
1 = Preview output
2 = Recording
output
REFMODE
Xm Xm Follow mode requested by user
Rd/Wr 0
5
0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
1 = Preview output
2 = Recording
output
REFCURRENTMODE
Xc Xc
Current follow mode
Rd/Wr 0
5
0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
1 = Preview output
2 = Recording
output
REFFREQ
Xt
Xt
Frame rate of the reference signal Rd
0
65535 0
Unit = 1/100Hz
0 = Main output
1 = Preview output
2 = Recording
output