beautypg.com

Analog Way Digi Scan 1600 - DSV1600 User Manual

Page 26

background image

APPENDIX A / ANNEXE A

SCAN 1600 / DIGI SCAN 1600

PAGE 26

COMMAND RESPONSE

COMMAND DESCRIPTION

VALUE /VALEUR

COMMANDE RÉPONSE

DESCRIPTION DE LA COMMANDE

TYPE

MIN MAX

DESCRIPTION

STATUS COMMANDS / COMMANDES D’ETAT

U

UNIT

Measures unity in kHz.

Rd

0 65535

il

ILD

This command allows to calculate the
input line frequency in kHz

Rd

0 65535 Line frequency (in kHz) = (UNIT VALUE)

÷

(ILD VALUE).

id

IFD

This command allows to calculate the
input frame frequency in Hz.

Rd

0 65535 Frame frequency (in Hz) = (Line frequency in

Hz)

÷ (IFD VALUE).

ik

IST

Input sync type detection

Rd

0

3

0 = separate H & V
1 = Composite sync (TTL)
2 = SOG (Sync On Green)
3 = Composite sync (analog)

ip

IPS

Input sync detection.

Rd

0

1

0 = no sync detected 1 = sync detected

ih

IHP

Sign of the horizontal input sync.

Rd

0

1

0 = negative

1 = positive

iv

IVP

Sign of the vertical input sync.

Rd

0

1

0 = negative

1 = positive

ii

IIN

Interlaced signal detection.

Rd

0

1

0 = not interlaced

1 = interlaced

io

IOO

Status of the signal in comparison with
the input range frequency.

Rd

0

1

0 = in range

1 = out of range

if IFA

Input

format detection

Rd

0

8

0 = no signal
1 = "out of range" signal.
2 = VGA1 350l
3 = VGA2 400l
4 = VGA3 480l
5 = SVGA
6 = XGA
7 = SXGA
8 = UXGA

GA

REFA

Status of the synchronization mode

Rd

0 2

0

=

internal

1 = genlock
2 = wrong signal.

GF

REFF

Status of the synchronized format
(genlock).

Rd

0

2

0 = no signal
1 = NTSC 59.94 Hz.
2 = PAL 50 Hz.

GT

REFT

Frame frequency of the synchronized
signal (genlock) (in hundredth of Hz)

Rd

0 65535

NOTE: Rd = Read only command / Commande de lecture.

Rd/Wr = Read and write command / Commande de lecture et d'écriture.

This manual is related to the following products: