Analog Way BROAD SCAN - Ref. BSC730 Programmer's Guide User Manual
Page 7
COMMAND
RESPONSE
COMMAND DESCRIPTION
TYPE
VALUE /VALEUR
COMMANDE
RÉPONSE
DESCRIPTION DE LA COMMANDE
MIN
MAX
DESCRIPTION
LOGOS/FRAME COMMANDS / COMMANDES DU LOGO/FRAME
LM
LM
Frame/logo mode.
Rd/Wr
0
6
0 = use mode.
1 = logo recording mode.
2 = animated logo recording mode
3 = frame recording mode.
4 = erasing logo mode.
5 = erasing frame mode.
6 = logo transfer mode.
LX
LX
Status of the logo programmer
Rd
0
4
0 = free.
1 = logo/frame in recalling process.
2 = logo/frame in storing process.
3 = output format incompatible with the logo.
4 = logo/frame in erasing process.
LA
LA
Logo assignment.
Rd/Wr
0
5
0 = no logo
1 = logo 1...................
4 = logo 4
5 = animated logo
LC
LC
•
In logo recording mode: Number of the logo to be store
(1 to 5).
•
In frame recording mode: Number of the frame to be
store (1).
•
In erase logo mode: number of the logo to be erase (1 to
5)
•
In erase frame mode: number of the frame to be erase
(1).
Rd/Wr
0
5
In erase mode: 0 = erase all
LD
LD
Display logo (according to PC command)
Rd/Wr
0
1
0 = Display OFF
1 = Display ON
LU
LU
Horiz. position of the logo storing area.
Rd/Wr
0
255
Lu
Lu
Vert. position of the logo storing area.
Rd/Wr
0
255
LK
LK
Horizontal size of the logo storing area.
Rd/Wr
5
255
5 = 3%
255 = 100%
Lk
Lk
Vertical size of the logo storing area.
Rd/Wr
5
255
5 = 3%
255 = 100%
LQ
LQ
Pixels number in a line of the storing area.
Rd
0
65535
Lq
Lq
Lines number of the storing area.
Rd
0
65535
LH
LH
Horizontal position of the logo.
Rd/Wr
0
255
LV
LV
Vertical position of the logo.
Rd/Wr
0
255
LW
LW
Logo horiz. size % output format.
Rd
5
255
5 = 3%
255 = 100%
LS
LS
Logo vert. size % output format.
Rd
5
255
5 = 3%
255 = 100%
Lx
Lx
Logo type.
Rd
0
2
0 = incrusting logo