Section 4. Operation
Using Multiple Supplies

Split Supply

Operation

Split supply operation uses two power supplies to obtain two positive voltages with
a common ground, or to obtain a positive-negative supply.

Two Positive Voltages

To obtain two positive voltages, join the negative output

terminals of both supplies in a common connection as shown in

Figure 4.4

. The

positive output terminals provide the required voltages with respect to the common
connection.

Figure 4.4 Split Supply Operation of Multiple Supplies (two positive voltages)

Positive-Negative Supply

To obtain a positive-negative supply, connect the

negative output terminal of one supply to the positive terminal of the second supply
as shown in

Figure 4.5

. The positive output terminal of the first supply now provides

a positive voltage relative to the common connection. The negative output terminal
of the second supply provides the negative voltage. The current limits can be set
independently of each other. The maximum current available in split operation is
equal to the rated output of the supplies.













Operating Manual for HPD Series Power Supply

Postive Sense

Positive Output

Terminal

Negative Output

Terminal

Return Sense

Load Lines

Use the largest gauge and
shortest length possible

Power Supply 1

Postive Sense

Positive Output

Terminal

Negative Output

Terminal

Return Sense

Positive Load

Terminal #1

Postive Load

Terminal #2

Negative Load

Terminal

Load

Power Supply 2

26