Section 4. Operation


Introduction


Once you have installed the power supply and have connected both the AC input
power and the load as covered in

Section 2, “Installation”

, the power supply is ready

to operate.

“Operating Modes”

, below, offers a brief explanation of Constant Voltage and

Constant Current Mode operation.

“Connecting Multiple Supplies in Series (Voltage Mode Only)” on page 36

,

covers using multiple supplies.

Operating Modes

Your power supply has two basic operating modes: Constant Voltage Mode and
Constant Current Mode. The mode in which the power supply operates at any given
time depends on the combination of:

Output voltage setting V

SET

Output current limit setting I

SET

Resistance or impedance of the attached load R

L

Figure 4.1

represents the relationships between these variables.

Output

Voltage

Constant Voltage
Mode Region

R

L

>

V

SET

I

SET

V SET






O

O

Crossover Point


Constant Current

Mode Region


Output
Current

I SET

R

L

=

V

SET

I

SET

R

L

<

V

SET

I

SET






Where:

R

L

= Load Resistance

V

SET

= Output Voltage Setting

I

SET

= Output Current Setting

Figure 4.1 Relationship Between Operating Mode Variables

Note
The control circuits have been designed to allow you to set output voltage and current
up to 5% over the model-rated maximum values. The power supply will operate within
these extended ranges, but we cannot guarantee full performance to specification.

21