Section 1. Features and Specifications

Additional Electrical Specifications

Additional Electrical Specifications

Voltage Mode Transient Response
(Time for the output voltage to
recover to ±50 mV band for 50%
load change in the range of 25% to
100% of the rated load.)

Time delay from power on until
output stable

<500

s




1.5 s maximum

Input Conditions

Rated AC Input Voltage

120 Vac standard; 230/240 Vac AC200 option

Maximum AC Input Power

625 VA

Operational AC Input Voltage Range Single Unit: 104

127 Vac at 6 Arms

Dual Unit: 104

127 Vac at 12 Arms

AC 200 Option

Single Unit: 200

250 Vac at 3 Arms

Dual Unit: 200

250 Vac at 6 Arms

Maximum Input Current (per unit) at 6 A maximum at 104 Vac
nominal power line impedances

Input Frequency Range

47

63 Hz






















5