Figure 2.4 User Signals J7 Connector
J7-1 External TTL shutdown input signal
J7-2 Polarity signal, open collector
(asserted by VSET -x)
J7-3 Isolation signal, open collector
(asserted by OUT OFF)
J7-4 Fault signal, open collector
(asserted when bit set in fault register)
J7-5 External Vcc, 18V maximum
(supplied by connecting and operating an external source)
J7-6 External ground and shutdown return
(supplied by connecting and operating an external source)
J7-7 Open collector user signal
(asserted by AUXA ON)
J7-8 Open collector user signal
(asserted by AUXB ON)