Installation and Configuration
Remote/Local Operation

22

Operating Manual for GPIB for XT/HPD Series Power Supply

Table 2.4 Remote Mode Power On Conditions

LOC

Command

The LOC command overrides the Remote/Local switch. Use LOC to enable or
disable one or all slave supplies to operate in local mode. See “Command Reference”
on page 40.

Condition

Default Settings

7.5-140 Model Example

Voltage

0 V

VSET 0

Current

0 A

ISET 0

Soft Voltage Limit

VMAX (see models)

VMAX 7.5

Soft Current Limit

IMAX (see models)

IMAX 140

OVP Trip Voltage

Model VMAX + 10%

OVSET 8.25

Delay

0.5 s

DLY 0.5S

Foldback Protection

OFF

FOLD OFF

Output

ON

OUT ON

Hold

OFF

HOLD OFF

Unmask

NONE

UNMASK NONE

Service Request Capability

OFF

SRQ OFF

AUXA

OFF

AUXA OFF

AUXB

OFF

AUXB OFF