beautypg.com

AMETEK HPD Series User Manual

Page 19

background image

Installation and Configuration

Initial Inspection

17

Figure 2.3 GPIB Interface PCB

JUMPER SELECTION

J217

Local OVP control selection

[closed] [default]. See page 19.
[open] Front Panel OVP Control.

J117

User TTL shutdown (S/D) selection

[1-2] User TTL S/D line active low.
See page 26.
[2-3] [default] User TTL S/D line active high.

J217

Local Mode Disable Selection

[closed] [default]. See page 23.
[open] Software control of power supply only

Note: All other jumpers are not user-selectable.

LED INDICATORS

CR141

Red Diagnostic LED

Bus error or soft restart on Slave circuitry.

CR14

Red Diagnostic LED

Soft restart on Master circuitry.

CR13

Green Diagnostic LED

Bus error on Master circuitry.

EPROMS

U958

Slave EPROM

See revision number stamped on EPROM.

U18

Master EPROM

See revision number stamped on EPROM.

CONNECTORS

J6

IEEE 488 Bus Connector (J8 on rear panel subplate)

J10

User Signal Connector (J7 on rear panel subplate)