8.1. Installation of the rack with

ventilation facilities

To facilitate the renewal and circulation of the air

inside the rack, to reduce the temperature of the

units and thus improving their characteristics, it is

advisable to place 2 ventilation units of 25W, par-

ticularly when the rack with the MUX DVBS2_QAM/

COFDM CI Twin T-0X is located in warm places, with

temperatures higher than 45°C.

These ventilators will be installed on a tray that is

fixed inside the cabinet (fig. 1 & 2). This way, the

ventilators will force the fresh air entering from

the base of the cabinet, to circulate between the

modules and be expelled through a gap on top of

the cabinet (3-5 cm approx.). See fig. 3.

8. Norms for rack mounting (Max. 49 MUX CI T-0X - 7 subracks with 5 units in height - 8,7”)

Frontal

Subrack

fig. 1

fig. 2

fig. 3