beautypg.com

D versions menu, C temperature measurement menu, B configuration menu 2 – Televes T.0X DVBS2-COFDM CI TWIN MUX 3TP(2SAT):2CH User Manual

Page 21

background image

EN

21

TEMPERATURA

Act: 04

Max: 05

reset

TEMPERATURE

Now: 04

Max: 05

reset

Operating temperature ranges are scaled from 0 to

10 in the following way:

0 to 6 Optimum temperature range.

7 to 8 High temperature range.

9 to 10 Too high temperature

.

Should the temperature be out of the optimum

temperature range, please provide adequate

cooling to reduce it.

In case of using a wall mount cabinet, Ref. 5069, to

accommodate these modules MUX DVBS2-QAM

and COFDM CI, and the temperature was out of

the optimum range in any module of the headend,

make use of the ventilation unit Ref. 5334.

To check whether this change is effective or not,

reset the maximum recorded and then check again

the temperature after a time deemed appropriate.

5.2.d Versions menu

This menu displays the firmware version for

the unit as well as the one of the QAM/COFDM

modulator.

be applied either for demodulator A or

demodulators B and C.

»

CONFIG

LOOP: ON

LNB : 17V~

CONFIG

LOOP: ON

LNB : 17V~

CONFIG

LOOP: OFF

LNB A: 17V~

LNB BC: 13V

CONFIG

LOOP: OFF

LNB A: 17V~

LNB BC: 13V

CONFIG

LOOP: ON

LNB : 17V~

CONFIG

LOOP: ON

LNB : 17V~

CONFIG

LOOP: OFF

LNB A: 17V~

LNB BC: 13V

CONFIG

LOOP: OFF

LNB A: 17V~

LNB BC: 13V

» LNB power voltage Lets you select one of the

four available satellites (A, B, C and D), by

using DiSEqC commands whenever it is

necessary (e.g. a multiswitch output). 0

Vdc; 13 Vdc; 13 Vdc+22 KHz tone; 17 Vdc;

17 Vdc+22 KHz tone.

Symbol ~ on the RCU screen means 22

KHz. If you choose option “0 volts” for the

LNB, it disables any satellite selection.

5.2.c Temperature measurement

menu

This menu shows the current measured

temperature, and the peak in º C.

The maximum recorded temperature may also be

reset by press and holding the (more than 3 sec).

5.2.b Configuration menu 2

This menu allows to select the number of unit

inputs, as well as controlling the LNB powering and

the DiSEqC command for each one of the enabled

inputs.
Although the product has 3 demodulators A, B

and C, the signals can come from a single input

port (in which case the second port functions as an

input loop-through), or from the two input ports,

in which case the signal distribution is done as

follows:

input port 1

to demodulator A

input port 2

to demodulators B and C.

Choices are the following:

Number of inputs LOOP-THROUGH

» ON The second connector works as an

output for the signal coming in through

the first connector, and thus this signal

is available for serving another module.

Demodulators A, B and C receive the

same signal.

CONFIG

LOOP: ON

LNB : 17V~

CONFIG

LOOP: ON

LNB : 17V~

CONFIG

LOOP: OFF

LNB A: 17V~

LNB BC: 13V

CONFIG

LOOP: OFF

LNB A: 17V~

LNB BC: 13V

» OFF This choice configures the second

connector of the unit as an independent

input, and therefore will supply the

signal to demodulators B and C. This can

This manual is related to the following products: