OPERATING FIREPLACE
Continued
MANUAL LIGHTING
PROCEDURE
1.. Remove.glass.door.(see.Removing/Re-
placing Glass Door, page 18).
.. Follow.steps.1.through.8.under.Lighting
Instructions, page 20).
3.. Press.gas.control.knob.and.light.pilot.with.
match.
4.. Keep.gas.control.knob.pressed.in.for.30.
seconds. after. lighting. pilot..After. 30. sec-
onds, release gas control knob. Follow
steps.10.through.11.under.Lighting Instruc-
tions, page 20).
5.. Replace.glass.door.(see.Removing/Re-
placing Glass Door, page 18).
ELECTRONIC IGNITION
SySTEM
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information,
page.0.
2. Turn off all electrical power to the fire-
place.
3.. Turn.wall.switch.to.the.OFF.position.
4.. Open.lower.louver.panel.
5.. Turn. equipment. shutoff. valve. clockwise.
. to. the. OFF. position. (see. Figure.
34)..Do.not.force.
6. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information, page 20. If you don’t
smell.gas.go.to.the.next.step.
7.. Turn. equipment. shutoff. valve. counter-
clockwise.
.to.the.ON.position..Do.
not.force.
8.. Close.lower.louver.panel.
9. Turn on all electric power to fireplace.
10..Turn.wall.switch.to.the.ON.position.
Figure 35 - Pilot
Pilot.
Burner
Ignitor
Sensor.
Rod
Figure 34 - Turning Equipment Shutoff
Valve to the OFF Position
11..Visually.locate.pilot..Ignitor.should.begin.
to. spark. and. main. burner. should. ignite.
once flame appears at pilot.
• If lighting appliance for the first time each
season, it may take several attempts
before. supply. gas. can. reach. pilot. and.
main.burner.
•.If.appliance.will.not.stay.lit.after.several.
attempts, follow instructions in To Turn
Off Gas To Appliance, and call your
service.technician.or.gas.supplier.
NOTICE: During initial operation
of a new heater, the burning of
residues from the manufacturing
process of the firebox and logs
will produce a paper-burning smell
and orange flames. Open a window
for the first few hours of operation
to adequately vent this smell.
TO TURN OFF GAS
TO APPLIANCE
1.. Turn.off.wall.switch.
.. Turn.off.all.electric.power.to.appliance.if.
service.is.to.be.performed.
3.. Open.lower.louver.panel.
4.. Turn. equipment. shutoff. valve. clockwise.
.to.OFF..Do.not.force.
5.. Close.lower.louver.panel.
OPTIONAL WIRELESS
REMOTE OPERATION
Note: The WRC receiver and hand-held
remote control kit must be purchased sepa-
rately (see Accessories, page 31). Follow
installation instructions included with the
remote control.
1.. Turn.equipment.shutoff.valve.to.ON.posi-
tion..You.can.now.turn.burner.on.and.off.
with.hand-held.remote.unit.