beautypg.com

Fireplace installation – Desa CB36N User Manual

Page 17

background image

www.desatech.com

117437-01D

17

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1.. Close.equipment.shutoff.valve.(see.Fig-

ure.5).

2. Pressurize supply piping system by either

opening. propane/LP. supply. tank. valve.
for propane/LP gas fireplace or opening
main.gas.valve.located.on.or.near.gas.
meter for natural gas fireplace or using
compressed.air.

3. Check all joints from propane/LP supply

tank. or. gas. meter. to. equipment. shutoff.
valve (see Figure 26, for propane/LP or
Figure 27, for natural gas). Apply noncor-
rosive leak detection fluid to all joints.
Bubbles.forming.show.a.leak..Correct.all.
leaks.at.once.

FIREPLACE INSTALLATION

Continued

Figure 25 - Equipment Shutoff Valve

Open

Closed

Equipment.
Shutoff.Valve

Figure 26 - Checking Gas Joints for

Propane/LP Gas Fireplace

Propane/LP.
Supply.Tank

Gas.Valve

Equipment.Shutoff.Valve

Figure 27 - Checking Gas Joints for

Natural Gas Fireplace

Gas.
Meter

Gas.Valve

Equipment.
Shutoff.
Valve

PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1.. Open.equipment.shutoff.valve.(see.Fig-

ure.5).

.. Open. propane/LP. supply. tank. valve. for.

propane/LP fireplace or main gas valve
located.on.or.near.gas.meter.for.natural.
gas fireplace.

3. Make sure control knob of fireplace is in

the.OFF.position.

4. Check all joints from equipment shutoff

valve to gas valve (see Figure 26, for
propane/LP or Figure 27, for natural gas).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
Correct.all.leaks.at.once.

5. Light fireplace (see Operating Fireplace,

page 20). Check all other internal joints
for.leaks.

6. Turn off fireplace (see To Turn Off Gas to

Appliance, page 20 or 21 depending on
your.model).

LOUVER PANELS AND GLASS
DOOR

CAUTION: Do not operate

this fireplace with a broken glass

door panel or without the glass

door panel securely in place.

For replacement part informa-

tion see Replacement Parts,

page 31.

CAUTION: Wear gloves and

safety glasses while handling

or removing broken glass. Do

not remove if glass is hot. Keep

children and pets away from

glass.

WARNING: If fireplace has

been running, turn off and un-

plug fireplace. Let cool before re-

moving glass door or louvers.

This manual is related to the following products: