NEXCOM VTC 7100-C8SK User Manual
Page 19
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
5
Chapter 1: Product Introduction
VTC 71-C Series User Manual
Power Management
▪ Selectable boot-up & shut-down voltage for low power protection by
software
▪ Setting 8-level on/off delay time by software
▪ Status of ignition and low voltage status can be detected by software
▪ Support S3/ S4 suspend mode
Dimensions
▪ VTC 7100-C8SK: 260mm (W) x 176mm (D) x 90.1mm (H)
(10.24”x 6.93”x 3.51”) 4 Kg (8 Lb)
▪ VTC 7110-C4SK: 260mm (W) x 176mm (D) x 90.1mm (H)
(10.24”x 6.93”x 3.51”) 4 Kg (8.81 Lb)
▪ VTC 7120-C4SK: 60mm (W) x 176mm (D) x 90.1mm (H)
(10.24”x 6.93”x 3.51”) 4 Kg (8.81 Lb)
Construction
▪ Aluminum enclosure with fanless design
Environment
▪ Operating temperatures:
Ambient with air: -30°C to 50°C (VTC 7110 / 7120 series)
Ambient with air: -30°C to 55°C (VTC 7100 series)
▪ Storage temperatures: -35°C to 85°C
▪ Relative humidity: 10% to 90% (non-condensing)
▪ Vibration (random): 1g@5~500 Hz (in operation, SSD)
▪ Vibration (SSD):
Operating: MIL-STD-810G, Method 514.6, Category 4, common
carrier US highway truck vibration exposure
Storage: MIL-STD-810G, Method 514.6, Category 24, minimum integrity test
▪ Shock (SSD):
Operating: MIL-STD-810G, Method 516.6, Procedure I, functional shock=20g
Non-Operating: MIL-STD-810G, Method 516.6, Procedure V, crash hazard
shock test=75g
Certifications
▪ CE approval
▪ FCC Class A
▪ e13 Mark
Power Management
▪ Power-on delay time is selectable by BIOS to disable and enable in 10sec /
30sec / 1min / 5min / 10 min / 15min / 30min / 1hr.
▪ Power-off delay time is selectable by BIOS to disable and enable in 20sec /
1min / 5min / 10min / 30min / 1hr / 6hr / 18hr.
▪ S3, S4 suspend mode
▪ Ignition On/Off status detectable by SW
▪ Low battery status detectable by SW
▪ Ignition enable/disable is jumper selectable
▪ Shut down system automatically when the system’s internal temperature
is over 80C.
▪ VTC 71 series will automatically shut down 5 minutes after the duration
of low battery voltage is over 60 sec. User can detect this situation via
software.
▪ If the ignition is off and the system is still on after 3 minutes, VTC 71
series will shut down automatically.
▪ If the ignition is off, the user can detect this status via the software.
▪ If the ignition is turned on again and the power-off delay is in progress,
VTC 71 series will cancel the delay function and will continue to operate
normally.
▪ If the ignition is turned on again and the power-off delay ended,
VTC 71 series will shut down completely will power-on again
automatically.
▪ If the ignition is turned off again and power-on delay is in progress,
VTC 71 series will cancel the delay and stay in power-off status.
▪ If the ignition is turned off again and the power-on delay ended (entered
OS already), VTC 71 series will continue to operate normally.
▪ If the ignition is turned off again and the power-on delay ended (in BIOS
process), VTC 71 series will shut down immediately.
▪ If VTC 71 series is off, only below 10mA is used.