Appendix A: Power Consumption

Power Consumption Management

Purpose

The purpose of the power consumption test is to verify the power dissipation
of system, and the loading of power supply.

Test Equipment

PROVA CM-07 AC/DC CLAMP METER

Device Under Test

DUT: sys#1/

Test Procedure

1. Power up the DUT, boot into Windows 7 x64 Ultimate
2. Entering standby mode (HDD power down)
3. Measure the power consumption and record it.
4. Run Burn-in test program to apply 100% full loading
5. Measure the power consumption and record it.

Test Data

Sys #1

(Disabled Turbo Boot)

+24V

Full-Loading Mode

1.61A

Total

38.64W

Standby S3Mode

0.08A

Total

1.92W