Gfsw-216sf, Installation – Neotech Communications GFSW-216SF User Manual

Page 2

background image

GFSW-216SF

Unmanaged Rack Mount 16-port 100Base-FX SFP + 2-port 10/100/1000Base-TX Optical Ethernet Switch

V1.0

2

Installation

SFP Transceiver Module

You can select different SFP modules as required (Please refer to our SFP selection list for the

appropriate module).

To insert/remove the SFP, the procedures are as follows :

1. On the front panel, insert the SFP module into

the SFP port until it is securely locked.

2. Connect the optical fiber (1/2 core) to the LC connector(s) of the SFP.

3. To remove the SFP module, press down the lock of the LC connector of the

optical fiber to pull out the fiber cable.

4. Pull down the SFP lever and hold its position. Pull out the SFP module

from the SFP port.

Rack Installation

GFSW-216SF can be installed on a rack. The product has 4 mounting holes. Use 4 rack mount screws to

securely install the product in a 19” rack cabinet.