3. INSTALLATION
page 3-4 Operation manual b42, chapter 3 -installation-
Pin assignments
Pin
Signal name
I/O
Functions
1
T1 open contact
O
preset1 recalled
2
T2 open contact
O
preset2 recalled
3
T3 open contact
O
preset3 recalled
4
T4 open contact
O
preset4 recalled
5
T5 open contact
O
preset4 recalled
6
T6 open contact
O
preset4 recalled
7
T7 open contact
O
preset4 recalled
8
T8 open contact
O
preset4 recalled
9
T9 open contact
O
mute
10
T10 open contact
O
bypass
11
T11 open contact
O
Not used
12
T12 open contact
O
Not used
13
T13 open contact
O
Not used
14
T14 open contact
O
Not used
15
root
Common root contact
Electrical specification:
Tally output
type:
normally open relais contacts
Contact rating:
1A 24 VDC, 0,5 A 125 VAC
max. 30 W 62,5 VA
max. 60 VDC, 125 VAC
Pin1...14
Tally output
Open contact
Pin15
Common root
contact