Junger Audio b42 - Dynamics Processor User Manual
Page 16
3. INSTALLATION
page 3-2 Operation manual b42, chapter 3 -installation-
The digital dynamics processor b42 has a digital signal output
only. To the problem-free combination of following digital devices,
the digital signal processing can be locked to an external clock
reference. The selection of the corresponding input is made in
the SYNC MODE menu. If the chosen sync input is connected
with the sync signal, this signal is used for synchronization
automatically. The digital output signal can be clocked with the
following clock frequencies:
CH 1/2
locks with the clock frequency of the input signal at
digital input CH 1/2 (AES/EBU, 48 kHz)
EXT SYNC locks with the clock frequency at the
external sync input (AES/EBU, 48 kHz)
VIDEO
locks with the clock at the Video sync input
(internal 48 kHz)
SDI VIDEO locks with the clock at the SDI input
(internal 48 kHz)
Both digital outputs CH 1/2 and CH 3/4 are locked with same
clock frequency.
Note: SDI sync is available only if SDI interface is installed!
The digital dynamics processor b42 can be remote-controlled by
means of parallel GPI contacts.
use :
remote-controlled changeover of presets
connector:
D-SUB 15pin, female
Pin assignments
Pin
Signal name
Logic
I/O
Functions
1
PRESET1
H
I
recall preset1
2
PRESET2
H
I
recall preset2
3
PRESET3
H
I
recall preset3
4
PRESET4
H
I
recall preset4
5
PRESET5
H
I
recall preset5
6
PRESET6
H
I
recall preset6
7
PRESET7
H
I
recall preset7
8
PRESET8
H
I
recall preset8
9
MUTE
H
I
Muting outputs
10 BYPASS
H
I bypass
on
11 not
used
12 not
used
13 not
used
14
Common pin
External ground
15
+5V
O
Test power source
3.6
SYNCHRONIZATION
OF
DIGITAL OUTPUT
3.7
REMOTE
CONTROL
3.7.1
GPI REMOTE
CONTROL
(PARALLEL