C8702, C8000 – Junger Audio C8702 Controller C8000 User Manual
Page 22

C8000
Frame Controller
C8702
digital audio
modular
processing system
22/22
enhanced Bit Transparent mode
The SDI I/O modules generate a Non Audio flag that indicates if the de-embedded data are marked as
non audio.
Important Note! This information does not mean that there is NO audio.
This is the case for coded signals like Dolby E or Dolby Digital (AC3). These are data streams packed
into two ordinary audio channels as a transport container. Audio processing equipment must not modify
such data stream. Therefore you may turn the signal chain into the Bit Transparent mode.
In the past, the knowledge about such data streams came from external equipment or was gathered from
play lists of automation systems. Now the Junger processing channnel may be setup to
Bit Transparent mode = off / on / auto :