C8702, C8000, Frame controller – Junger Audio C8702 Controller C8000 User Manual
Page 14: Digital audio modular processing system

C8000
Frame Controller
C8702
digital audio
modular
processing system
14/22
First you get the message that the file is being transferred. Afterwards you will see a progress bar when
the process has started :
When finished, the browser will show a message :
Click
from the Frame Controller in order to be up to date.
emergency update of the Frame Controller firmware
If for any reason the standard process is not successful you must reboot the C8702 by briefly pressing the
open the browser again and enter the URL :
http://
The following page will open:
Proceed with the image update as described above. When finished you will get a pop up, saying the
update was o.k. (it takes approx. 4 - 5 mins – be patient :-).
Finally you must reset the C8702 manually either by briefly pressing the INIT button or by the
Reboot pane of the Frame Controller pages.
Important Note! We have changed the way the Frame Controller image is sent from the PC and the way
the image is burned into the flash memory to overcome a possible bottleneck of non fragmented RAM.
If you update from an older version (< 2660) you should reboot the Frame Controller before starting the
image update. This will ensure that there is enough non fragmented RAM for the existing update
procedure. In rear occasions it might be necessary that the update must be performed in a two tier
approach. Pls. contact Junger audio if the frame controller boots up with the old image loaded after the
update.