Enhanced 8 channel Level MagicII™ processor

C8086+

6/16


DOLBY METADATA

If the 8086+ has enabled the "M" (metadata) option this part of
the preset pane will appear as well.

Load

select a preset by name and press .

The loaded preset number and name will automatically appear in
the below Save as # and Name field.

Save as #

select a preset memory number where you
would like to save the actual audio program parameters to.

Name

assign the preset you are about to save a name (up to 16 digits)
and press .


SETUP/INPUT BUS ROUTING

a bank of 8 presets to recall device settings.

(FROM C8000 BUS)

Load

select a preset by name and press .

The loaded preset number and name will automatically appear in
the below Save as # and Name field.

Save as #

select a preset memory number where you would like to save the
actual audio program parameters to.

Name

assign the preset you are about to save a name (up to 16 digits)
and press .

Preset Clipboard

copy the active preset to a clipboard, the data may be used by
other modules inside the same frame.

Backup Presets to File

creates a backup XML file which may be stored to the PC.

Restore Presets from File

you can select [browse] a backup file from the PC.



STATUS DISPLAY

If you are controlling a specific module you will see a status frame on the left
hand side that also appears if you hover with the mouse over the graphical boxes
in the GUIs OVERVIEW display. If the GUI size does not fit your screen well you
may decrease the size of the status display by clicking on the little arrows in the
upper left edge to get a smaller view.

If you click on the "metering" symbol
in the bottom of that display, an applet
will be downloaded from the frame
controller, that shows the level display :


A JAVA Runtime Environment must be
installed on the PC to run that applet.
The metering data will be streamed
via UDP protocol to the PC.

Make sure that you have opened the Windows fire wall
for the required UDP port (see C8702 manual for details). If no UDP data are received by the applet,
the meters will turn red from black. Since Java SE 7u21 an applet must be signed with a trusted
certification. Junger Audio has certified its applets. You must have at least C8702 frame controller
firmware 1.17.x in order to get it right. Details from ORACLE you will find here :

http://www.oracle.com/technetwork/java/javase/tech/java-code-signing-1915323.html

.