C8086, C8000 – Junger Audio C8086+ - Level Magic II ™ processor User Manual
Page 16
Rev. 140416
digital audio
modular
processing system
C8000
Enhanced 8 channel Level MagicII™ processor
C8086+
16/16
GPOs are meant to present status information to external devices. A C8k frame can handle 127
independent virtual GPO numbers. You must assign a unique number to the respective
preset / function. In case a preset is loaded either manually via the GUI or remotely via the
brc8x or via a GPI/O module, the assigned number will be broadcasted over the CAN bus.
A GPI/O module which has that number assigned to a physical output will engage that relay or a
brc8x may turn on an assigned button tally light.
Clear GPO on
If a GPO indicates that a certain preset is loaded and if you
Preset modified
change parameters which are related to that preset the word
"modified" will be displayed in line with the preset name in the
status window.
In this case you may clear that GPO to indicate that the
parameters are not the same as the content of the previously
loaded preset.
Important Note! GPOs from modules and GPIs to modules don't "see" each other.
I.e. you can't use a status GPO of module A to load a preset for module B by simply assigning
a GPO number of module A as a GPI number of module B. If this is a requirement you
must involve the GPI/O conversion function of the C8817 GPI/O module (see manual for details).